THE LAUREATE SERIES
Serial Comunications Manual
LAUREL Electronics Inc.
3183-G Airway Ave, Costa Mesa, CA USA 92626
Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com
Vista de pagina 0
1 2 3 4 5 6 ... 39 40

Indice de contenidos

Pagina 1 - THE LAUREATE SERIES

THE LAUREATE SERIESSerial Comunications ManualLAUREL Electronics Inc.3183-G Airway Ave, Costa Mesa, CA USA 92626Tel: (714) 434-6131 Fax: (714) 434-3

Pagina 2

The measurement data format with both of these parameters set consists of 10 characters:+999.99A<cr><lf> * *

Pagina 3

4.0 SYSTEM CONFIGURATIONSThe meters operate in a Point-to-point mode using RS-232 or RS-485. In addition, they canoperate in a Multi-point mode using

Pagina 4

Counter onlyThe transmission rate of measurement data can be selected in “Ser 1". Data transmission isinitiated at the end of the calculation ti

Pagina 5

At the end of the complete transmission, the latched RTS value is reset false, even though the RTSline may be high at that instant. The RTS latch do

Pagina 6

CHAR #1234CHARACTER*0-VA-Z0-UDESCRIPTIONCommand Identifier (Recognition Character)Device Address (0 addresses all devices, 1-Vspecific)Command Functio

Pagina 7

-14-COMMUNICATIONS MODEContinuous mode*1A0Command mode *1A1. REQUEST DPM/SCALE VALUE REQUEST COUNTER VALUESLatest reading *1B1 * All active items*1

Pagina 8

CHARACTER 4Code for number of bytes or wordsCode # Code # Code # Code #1 = 1 9 = 9 H = 17 P = 252 = 2 A = 10 I = 18 Q = 263 = 3 B = 11 J

Pagina 9

aa is the most significant address in nonvolatile memory of the wordsto be read or written<data> is n words of 2 bytes or 4 hex characters per w

Pagina 10

S = Sign of value, space (or +) for positive, - for neg value D = Digit from 0 to 9 . = Decimal point placement and must always be included A = Alarm

Pagina 11

Command Identifier “*”, the address #, and the Command letter “H”. This is thesame format that data is transmitted from a DPM in the Continuous mode

Pagina 12

CONTENTS1.0 HARDWARE AND SOFTWARE SETUP...21.1 SELECTING THE MODULAR CABLE TYP

Pagina 13

transmits up to 3 values) each measurement cycle, Modes 8-11 provide the abilityof the Remote Display to extract one of four sequential values and dis

Pagina 14

*= Recognition character# = Device address from 1-9, A to V, or 0 for common address.C = Command letter H, K, L.S = Sign of value, space (or +) for p

Pagina 15

-21-5.5 RECOGNITION CHARACTER AND START AND STOP CHARACTERSThe meter recognizes an asterisk ( * ) as the command recognition character. In the counte

Pagina 16

BF Analog Setup Bit 7 6 5 4 3 2 1 0 bit0 = Analog Out Unfiltered1 = Analog Out Filtered0 = Current Output1 = Voltage Output0 0 0 0 0 0 = Not used

Pagina 17

-23-31 Serial Cnfg1 Bit 7 6 5 4 3 2 1 0 Continuous Output Data Rate(continued) 0 1 1 1 18.1 21.81 0 0 0 36.3 43.51 0 0 1 72.3 86.70 0 0 300 baud0

Pagina 18

-24 -2C Alarm Cnfg2 Bit 7 6 5 4 3 2 1 0 Alarm Trigger Delay60 Hz 50Hz0 0 0 .018s .021s0 0 1 .035 .0430 1 0 .07 .0850 1 1 .14 .171 0 0 .28 .341 0 1 .56

Pagina 19

RAM HEX DATA TABLEMS Mid LSA1 A0 9F Analog high value9E 9D 9C Analog low value9B 9A 99 Deviation Alarm298 97 96 Deviation Alarm18F 8E 8D Offset value8

Pagina 20

6.2 COUNTER 1-BYTE RAM DATA TABLE Hex Address Name Bit Assignment43 Resolution Bit 7 6 5 4 3 2 1 00 0.00001 multiplier1 0.0001 mu

Pagina 21

-27-36 Lockout2 Bit 7 6 5 4 3 2 1 0 Bit=0 is unlocked for all items1 Change Item # locked1 CALib locked1 Ser 1, Ser 2, Ser 3 locked1 An Lo, An Hi, An

Pagina 22

-28-33 Serial Cnfg3 Bit 7 6 5 4 3 2 1 0 Transmit(Cont'd) 1 0 0 Peak value only1 0 1 All active items + Peak0 Termination chars end of all items o

Pagina 23

1.0 HARDWARE AND SOFTWARE SETUPThe word “modular” refers to telephone-type extension cable and connections.To connect a single meter to the computer

Pagina 24

-29-2E Setup Bit 7 6 5 4 3 2 1 0 EXTIN A EXTIN B0 0 0 0 Meter Reset Function Reset0 0 0 1 Meter Reset Hold0 0 1 0 Meter Reset Peak Display0 0 1 1 Mete

Pagina 25

-30-2C Alarm cnfg2 Bit 7 6 5 4 3 2 1 0 #Consecutive readings to Alarm0 0 0 10 0 1 20 1 0 40 1 1 81 0 0 161 0 1 321 1 0 641 1 1 1281 Alarm 1 Hystere

Pagina 26

NON-VOLATILE MEMORY ADDRESSES (2 bytes/address)Sign + Magnitude XXXX XXXX XXXX XXXX XXXX XXXX S=SignS Magnitude Sign = 1 for negativeSign+DP+Magnitud

Pagina 27

6.3 WEIGHT METER1-BYTE RAM DATA TABLE Hex Hex Address Item Name Value6B Configuration Bit 7 6 5 4 3 2 1 00 =

Pagina 28

-33-33 Lockout1 Bit 7 6 5 4 3 2 1 0 bit = 0 is unlocked for all items1 = Count locked1 = Setup, config and dEC.Pt locked1 = Input type locked1 = Chan

Pagina 29

2F Filter Bit 7 6 5 4 3 2 1 00 0 0 0 Auto Filter0 0 0 1 Batch (16 samples) filterTime constant 60 Hz 50 Hz0 0 1 0 Moving Average .07s .085s0 0 1 1 Mov

Pagina 30

3-BYTE RAM MEMORY DATA All items except Scale Factor use this format:Note: Hex value (2's complement) MS byte Mid byte LS byte X X

Pagina 31

Hex AddressesMS Mid LSA1 A0 9F Analog high value9E 9D 9C Analog low value9B 9A 99 Deviation Alarm298 97 96 Deviation Alarm18F 8E 8D Offset value8C 8B

Pagina 32

-38 -7.0 SOURCE LISTINGB & B Electronics Manufacturing Co.707 Dayton RoadOttawa, IL 61350Phone: (815) 433-5100Fax: (815) 433-5109Website: www.

Pagina 33

WARRANTYLaurel Electronics Inc. warrants its products against defects in materials or workmanship for aperiod of one year from the date of purchase.In

Pagina 34

1.2 RS232 AND RS485 WIRING CONNECTIONSThe cable connections to an IBM PC-compatible computer are different for RS232 and RS485.The RS232 cable connect

Pagina 35

Copyright 1996-2004 Laurel Electronics Inc. 06/04 Rev. E

Pagina 36

Another alternative for RS-485 is to use an RS-232 to RS-485 converter that plugs into thecomputer RS-232 receptacle external to the computer and is p

Pagina 37

1.3 RS-232 AND RS-485 JUMPERS SETTINGSRS232 InterfaceJumper g - installed for normal operationJumper h - installed when used as a slave display witht

Pagina 38

DIGIT SELECT KEYVALUE SELECT KEYMENU KEY Ser 1Serial interface setup(only enabled if communica-tions board installed) Ser 2Serial interface

Pagina 39

DIGIT SELECT KEY VALUE SELECT KEYMENU KEY 00000RS485 full or half duplex 00000Meter recognition characterand start & stop character 0000

Pagina 40

2.0 INTERFACE INFORMATIONThe series of DPMs and counters offers RS232 or RS485 serial communication interface boardsthat may be connected by cable to