Press Menu
Select Key
Press Digit
Select Key
Press Value Select
Key
000_0
Operation as a rate of
change meter.
Extended meter only.
0 Not rate of change
1 Rate x 0.1
2 Rate x 1
3 Rate x 10
4 Rate x 100
5 Rate x 1000
6 Rate x 10000
000_0
Operation of front
panel PEAK button
and rear connector for
Peak or Valley Display
0 Peak Display. Also selects “Peak” in
“Peak or Valley” at connector above.
1 Valley Display. Also selects “Valley” in
“Peak or Valley” at connector above.
2 Peak (1st push), Valley (2nd push)
3 Front panel Tare
000_0
Auto-tare
0 Meter comes up in normal run mode.
1 Meter comes up in auto-tare mode
ConFG
Meter Configuration
000_ 0
Nonlinear input scaling
Extended meter only.
0 Linear input
1 Custom curve linearization
00000
Alarm filtering
0 Unfiltered output
1 Filtered output
00000
Peak & Valley filtering
0 Unfiltered Peak & Valley
1 Filtered Peak & Valley
00000
Display filtering
0 Display batch average every 16 readings
1 Display filtered signal
00000 Adaptive filter
threshold
0 Low adaptive filter threshold level*
1 High adaptive filter threshold level
FiLtr
Filtering
00000
Input signal filtering.
Can be applied to dis-
play, setpoint, analog
output, data output.
0 Autofilter
1 Batch average, 16 readings
2 Moving average, 0.08 sec.
3 Moving average, 0.15 sec.
4 Moving average, 0.3 sec.
5 Moving average, 0.6 sec.
6 Moving average, 1.2 sec.
7 Moving average, 2.4 sec.
8 Moving average, 4.8 sec.
9 Moving average, 9.6 sec.
A Unfiltered
dEc.Pt
Dec. point selection
d
.
dddd
Decimal point flashes.
d
.
dddd dd
.
ddd ddd
.
dd dddd
.
d ddddd
.
.
ddddd