18
Press Menu
Select Key
Press Digit
Select Key
Press Value Select
Key
Scaling method “Scale and Offset” if selected under SEtuP
SCALE
Scale factor
0.0000 0.0000 0.0000
0.0000 0.0000
0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Select decimal point
location when decimal point is flashing.
OFFst
Offset value
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point
location is selected by dEC.Pt.
Scaling method “Coordinates of 2 points” if selected under SEtuP
Lo In.
Low signal input.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by input range chosen.
Lo rd
Desired reading at
Lo In.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by dEC.Pt.
Hi In.
High signal input.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by input range chosen.
Hi rd.
Desired reading at
Hi In.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by dEC.Pt.
Scaling method “Reading coordinates of 2 points” if selected under SEtuP
Lo In.
Low signal input.
_0.021
Apply a low reference
signal to the meter.
_0.021
Press to store the low signal input in the
meter.
Hi In.
High signal input.
_20.094
Apply a high reference
signal to the meter.
_0.021
Press to store the high signal input in the
meter.
Lo rd
Desired reading at
Lo In.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
0.0000
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by dEC.Pt.
Hi rd.
Desired reading at
Hi In.
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit to flash.
6.7500
Select -9 thru 9 for flashing first digit, 0 thru 9
for other flashing digits. Decimal point is set
by dEC.Pt.