Press Menu
Key
Press Digit Select
Key
Press Value Select
Key
_00000U Half or full duplex 0 Full duplex 1 Half duplex
_00000U
Recognition characters,
start & stop characters.
Special characters have to
be download via Instrument
Setup software.
0 * (asterisk) is recognition character.
No start & stop characters.
1 Custom recognition character.
No start & stop characters.
2 * (asterisk) is recognition character.
Special start & stop characters.
3 Custom recognition characters.
Special start & stop characters.
_00000URTS mode 0 Normal RTS 1 Single transmission
_00000U
CR (LF) termination cha-
racters.
0 Only at end of all items
1 At end of each item
.Ser 3.
Serial Setup 3
_00000U
Data sent in continuous
mode
0 All Active Items
1 Item #1 only
2 Item #2 only (if active)
3 Item #3 only (if active)
4 Peak only
5 Displayed Item
6 Valley only
7 All Active Items + Peak + Valley
___000U
Modbus* ASCII gap timeout
0 1 sec
1 3 sec
2 5 sec
3 10 sec
___000U
Serial protocol
0 Custom ASCII*
1 Modbus* RTU
2 Modbus* ASCII
Ser 4.
Serial Setup 4
___000U
Parity
0 None
1 Odd
2 Even
_Addr
Modbus Address
___000 ___000 ___000
Select digit to flash.
__158
Select 0 thru 9 for flashing digit.
Address range is 1 to 247.
* See Glossary for explanation of item.