36
Press
Menu
Press Digit
Select Key
Press Value Select
Key
_00000 & _00000 0 Not used with VF Batch. Set to 0.
_00000
Batch triggering
0 Use gate time* as delay between batches.
1 Use External Input B to start each new batch.
_00000
Definition of Item #2
0 Make Item #2 the Grand Total of all batches.
1 Make Item #2 the Total Number of batches.
bAtCH
Batch setup
_00000
Action after Meter Reset
0 Display “rEAdy.” RESET key starts batching.
1 Start batching upon Meter Reset.
_00000
Signal filtering
0 Adaptive moving average filter. Restarts filter for
high actual changes in signal.
1 Conventional moving average filter without reset.
_00000
Peak & Valley filtering
0 Peak* or Valley* value from unfiltered signal.
1 Peak* or Valley* value from filtered signal.
_00000
Display filtering
0 Display value of unfiltered signal.
1 Display value of filtered signal.
_00000
Adaptive filter setup
0 Set adaptive filter for normal noise.
1 Set adaptive filter for presence of high transients.
FiLtEr
Filtering
_00000
Filter time constant
0 No filter 1 0.1 sec 2 0.2 sec 3 0.4 sec
4 0.8 sec 5 1.6 sec 6 3.2 sec 7 6.4 sec
dEC.Pt1
Decimal pt1
1
.
11111
Decimal point flashes.
1
.
11111 11
.
1111 111
.
111 1111
.
11 11111
.
1 111111
.
Press to shift the decimal point.
dEC.Pt22
Decimal pt2
2
.
22222
Decimal point flashes.
2
.
22222 22
.
2222 222
.
222 2222
.
22 22222
.
2 222222
.
Press to shift the decimal point.
Scale and Offset scaling method if selected under SEtuP
SCALE1
Scale
Factor 1
0.00000 0.00000 0.00000
0.00000 0.00000 0.00000
Select the digit to flash
for the Scale Value, then
press one more time
for the Scale Multiplier.
Select -9 thru 9 for flashing first digit and 0 thru 9 for
other flashing digits. This will set the Scale Value*
from -9.99999 to 9.99999 with a fixed decimal point.
Then press to select a value from 0.00001 to
100000 in decade steps for the Scale Multiplier.
Scale Factor = Scale Value x Scale Multiplier.
OFFSt1.
Offset 1
000000 000000 000000
000000 000000 000000
Select digit to flash.
Select -9 thru 9 for flashing first digit and 0 thru 9 for
other flashing digits. Use dEC.Pt1 to set the decimal
point.
SCALE2 Scale Factor 2. Make the same Scale Factor 1.
OFFSt2. Offset 2. Make the same as for Offset 1.
Comentarios a estos manuales