-33-
MENU KEY
DIGIT SELECT KEY VALUE SELECT KEY
Press to display decimal
point location.
Press the key to
display dEcPt (Decimal
point).
Press
to change decimal
point location.
Press to display status.
Press again to select
digit. Selected digit will flash.
Press
to select value.
Digit 2:"1"= Reading input 2
coodinate method of scal-
ing.
1 2 3 4 5
Press the key to display
ConFG(configuration). See
Section 9, Pg 13 for detailed
description of digits 1 thru 5.
Press the key. Continue to press (or and
simultaneously) until rESEt
is displayed. The meter will go to the operating mode and display the value of the input signal.
Press to display value
and select left digit. Press
again to select another digit.
Decimal point set by dEc.Pt .
Press the key to display
Hi rd (Desired meter reading
at high signal input).
Use
to set digit values
and set to 500.00.
Press the key to display
Lo in (Low signal input value).
Apply an input for a known
low value.
Use to store reading as
low input
Press
to display input
signal. Meter will momen-
tarily blank and then display
a reading.
Use t o set digit values
and set to 20.000mV.
Press the key to display
Hi in (High signal input value).
Apply an input for a known
high value.
Press the key to display
Lo rd (Desired meter reading
at low signal input).
Press to display value and
select left digit. Press
again to select another digit.
Decimal point set by dEc.Pt
Use
to set digit values
and set to 0.
Press to display input sig-
nal. Meter will momentarily
blank and then display a read-
ing.
Press the key. Continue to press (or and
simultaneously) until
rESEt is displayed. The meter will go to the operating mode and display the value of the input
signal.