Laurel-electronics LAUREATE SERIES DPM Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
-10-
DIGIT SELECT KEY VALUE SELECT KEY
MENU KEY
Press
to select "0" or "1"
for flashing digit
2 - Alarm Setup
3 - Alarm setpoint value
programming
4 - Analog output scaling
5 - Serial interface setup
Press the
key until Loc
2 is displayed.
2 3 4 5
Press
to display status
and select left digit. Press
again to select another
digit. Selected digit will flash.
"1" indicates the menu item
is disabled. "0" indicates the
item is enabled.
Press
to select "0" or "1"
for flashing digit
2 - View peak value
3 - View alarm setpoints
4 - Reset (peak and latched
alarms)
5 - Reset (meter reset)
Press the key until Loc
3 is displayed. Lockout 3
controls the operation of the
front panel push-buttons
when the meter is in the nor-
mal mode of operation.
2 3 4 5
Press to display status
and select left digit. Press
again to select another
digit. Selected digit will flash.
"1" indicates the menu item
is disabled. "0" indicates the
item is enabled.
10. SETUP MENU
VALUE SELECT KEY
MENU KEY
DIGIT SELECT KEY
INPUT SIGNAL SCALING METHOD
Lo in
Low signal input value
(not available for tC & rtd)
Hi In
High Signal Input Value
Lo rd
Set Low Displayed Reading
for Low Signal Input
Hi rd
Set High Displayed Reading
for High Signal Input
0.021
Set the input signal to zero or
a known low value
20.094
Set the input signal to a
known high value
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit. Digit will flash
0.0000 0.0000 0.0000
0.0000 0.0000
Select digit. Digit will flash
0.021
Press the
key to store the
low signal input.
20.094
Press the
key to store the
high signal input.
0.000
Select 0 through 9 for
flashing digit. Decimal point
location is fixed by dEC.Pt.
0.000
Select 0 through 9 for
flashing digit. Decimal point
location is fixed by dEC.Pt.