1
LAUREATE SERIES
SCALE / WEIGHT METER OWNERS MANUAL
Now with USB & Ethernet
LAUREL Electronics Inc.
3183-G Airway Ave, Costa Mesa, CA, 92626, USA
Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com
Vista de pagina 0
1 2 3 4 5 6 ... 42 43

Indice de contenidos

Pagina 1 - LAUREATE SERIES

1 LAUREATE SERIES SCALE / WEIGHT METER OWNERS MANUAL Now with USB & Ethernet LAUREL Electronics Inc. 31

Pagina 2 - 1. ORDERING GUIDE

10 Note: Corresponding main board and option board connectors have the same number of electrical lines. When an option board is correctly

Pagina 3 - 2. TABLE OF CONTENTS

11 9. FRONT PANEL SETUP KEYS Meter Front Panel There are four front panel keys, which change function for the Run Mode and Menu Mode, effectively

Pagina 4 - 3. PRODUCT INTRODUCTION

12 KEYS IN MENU MODE Right Arrow Key (MENU). Pressing steps the meter through all menu items that have been enabled and then back to the

Pagina 5

13 10. ENABLING & LOCKING OUT MENU ITEMS For security reasons and ease of meter operation, any and all menu items may be disabled

Pagina 6 - 6. SAFETY CONSIDERATIONS

14 11. PROCESS & STRAIN INPUT JUMPERS Process and strain input scale meters utilize the DC signal conditioner board, which offers

Pagina 7 - P4 – SIGNAL INPUT

15 12. LOAD CELL INPUT JUMPERS Notes 1. See Section 17 to select 10V excitation. 2. Jumpers are 2.5 mm (0.1 in). 3. Store spare jump

Pagina 8 - RS485 INTERFACE - HALF DUPLEX

16 13. SCALE METER SETUP When the Reading Coordinates of 2 Points scaling method has been selected under SEtuP, the four menu items below will ap

Pagina 9 - 8. MECHANICAL ASSEMBLY

17 OTHER KEYSTROKES FOR SCALE METER SETUP If the MENU key does not work, see Section 10 “Enabling & Locking Out Menu Items.” Press Menu Se

Pagina 10

18 Press Menu Select Key Press Digit Select Key Press Value Select Key 00000 Negative readings 0 Allow negative readings 1 Disallow neg

Pagina 11 - 9. FRONT PANEL SETUP KEYS

19 FiLtr Filtering (continued) 00000 Input signal filtering. Can be applied to dis-play, setpoint, analog output, data output. 0 Autofilter

Pagina 12

2 1. ORDERING GUIDE Configure a model number in this format: LW20201SG1, CBL01 LW ... Laureate scale / weight meter Display Color 1 ...

Pagina 13 - Rd, Hi Rd

20 Option board dependent menu items ALSEt. -SP1-d -SP2-d Menu items related to alarm setup These will only appear if a relay board is detected

Pagina 14

21 14. DUAL RELAY OUTPUT OPTION An optional relay board may be installed in the scale meter main board at plug position P2, adjacen

Pagina 15 - 12. LOAD CELL INPUT JUMPERS

22 Press Menu Select Key Press Digit Select Key Press Value Select Key _SPI_d Alarm 1 dribble value 0.0000 0.0000 0.0000 0.0000 0.0000 Se

Pagina 16 - 13. SCALE METER SETUP

23 ALARM TYPES Latched alarms stay actuated until reset. They can shut down machinery or a process when a setpoint (or limit) has been exceeded or

Pagina 17

24 15. ANALOG OUTPUT OPTION An analog board may be installed in the meter at rear panel jack position J4, adjacent to the signal conditioner board.

Pagina 18

25 16. SERIAL COMMUNICATION OPTIONS A serial communications board may be connected to the meter main board at plug position P13 (middle position)

Pagina 19

26 Basic Ethernet Board No jumpers needed. RS232 Board e - Normal operation. f - Slave display to RS232 from another meter. g - Pull-up re

Pagina 20

27 SERIAL CONNECTION EXAMPLES

Pagina 21

28 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 10 “Enabling & Locking Out Menu Items.” Press Menu Select Key

Pagina 22

29 Press Menu Select Key Press Digit Select Key Press Value Select Key _0000U Line feed 0 No line feed after carriage return 1 Line feed

Pagina 23

3 2. TABLE OF CONTENTS 1. ORDERING GUIDE ...

Pagina 24 - 15. ANALOG OUTPUT OPTION

30 17. EXCITATION OUTPUT & POWER SUPPLY Three isolated transducer excitation output levels are available from the power supply board. These ar

Pagina 25

31 18. INSTRUMENT SETUP VIA PC Instrument Setup software is a PC program which is much easier to learn than front panel programming. It is of

Pagina 26

32 SETUP OF CONNECTED METER A setup file can be retrieved from the meter (DPM => Get Setup), be edited (View => Setup),

Pagina 27

33 Plot Graph • The Readings pull-down menu provides three formats to display DPM data on the PC monitor. Use the Pause and Continue

Pagina 28

34 To enter new setup information, click on View => Setup, then make your screen selections as if you were connected to a meter. Tabs will be gray

Pagina 29

35 20. SCALE METER SPECIFICATIONS Meter Display Type ...5 LED, 7-segment, 14.2mm (.56") high digits &

Pagina 30

36 DC, Process, Strain Signal Conditioner Range Resolution Resistance Zero Range Span Range Error 200.00 mV 2.0000 V 20.000 V 10 µV 100 µV 1 mV

Pagina 31

- 37 - Accuracy ...Meter input accuracy ±0.02% of full scale analog output Resolution ...

Pagina 32

- 38 - 21. GLOSSARY OF TERMS Adaptive Filter Threshold A threshold which causes an adaptive moving average filter to be reset to the latest read

Pagina 33

- 39 - Custom ASCII Protocol A simplified, short protocol for use with these panel meters. It allows 31 digital addresses. Not an industry-stand

Pagina 34

4 3. PRODUCT INTRODUCTION The Scale Meter is a compact, inexpensive, and extremely accurate digital panel meter with special firmware for weighing

Pagina 35

- 40 - Meter Hold A rear panel input which freezes the meter display and all meter outputs while that input is tied to logic ground by a switch or i

Pagina 36

- 41 - Reset There are three types of Reset:  Peak Reset. Achieved by simultaneously pressing the RESET and PEAK keys.  Latched Alarm R

Pagina 37

- 42 - voltage or current at either point does not need to be known. The decimal point is set by the separate dEC.Pt menu item. Setpoint A value com

Pagina 38 - 21. GLOSSARY OF TERMS

- 48 - 22. WARRANTY Laurel Electronics Inc. warrants its products against defects in materials or workmanship for a period of one year from the d

Pagina 39

5 4. ADVANCED OPERATING FEATURES • Setpoint offset. The ON/OFF setpoint control action can be programmed to occur with a specified offse

Pagina 40

6 5. RECEIVING & UNPACKING Your scale meter was carefully tested and inspected prior to shipment. Should the meter be damaged in shipm

Pagina 41

7 7. CONNECTOR WIRING INFORMATION CONNECTORS Connectors for signal and power are UL-rated screw-clamp terminal blocks that plug into mating jacks o

Pagina 42

8 P3 - SERIAL COMMUNICATIONS P4 - ANALOG OUTPUT N/CISO GNDRXTXRTSN/CGNDTXRXRTSRS232 INTERFACE Computer654321ISO GNDBRXARXATXBTXISO G

Pagina 43 - 22. WARRANTY

9 8. MECHANICAL ASSEMBLY REMOVING THE REAR PANEL First remove any connectors. Use one hand to press in the two sides of the rear of

Comentarios a estos manuales

Sin comentarios