SETTING UP COMMUNICATIONS (REMOTE A & S MODES)
The above screen will appear under the
Communication
tab if
Remote A
or
Remote S
has been
selected as
Display Type
under the
Input+Display
tab. These two modes are not able to extract data
from an ASCII string that contains multiple data values and non-numeric characters.
Under this tab, you can reselect your
Baud Rate
,
Device Address
,
Serial Protocol
, and
Full/Half
Duplex
, even though you may have selected different values to establish initial communications
with your PC.
Set
Output Mode
to
Command
. Ignore the setting for
CR(LF)
,
Output Items
,
Output Filter
, and
Output Rate
, as these items apply to digital transmission by a counter-transmitter, not to digital-to-
analog conversion by the serial input transmitter.